PROSOFT MVI56-MCM MVI56-MCMR Modbus Master/Slave Communication Module in stock

The ProSoft MVI56-MCM is a Modbus Master/Slave communication module for the Rockwell Automation ControlLogix platform. It acts as a gateway between the ControlLogix backplane and Modbus-compatible devices, enabling seamless data exchange with instruments, drives, and SCADA systems.

  • Item No :

    MVI56-MCM
  • Order(MOQ) :

    1 Piece
  • Payment :

    EXW
  • Product Origin :

    USA
  • Shipping Port :

    Wuhan
  • Lead Time :

    3-5days
  • Weight :

    0.5KG
  • Product Details

    • Part Number: MVI56-MCM

    • Product Type: Modbus Communication Module (Master/Slave) 

    • Platform: Rockwell Automation ControlLogix (1756 backplane), single-slot 

    • Communication Ports: 2 application ports + 1 configuration port (RJ45 connectors, supports RS-232/RS-422/RS-485) 

    • Protocol Support: Modbus RTU and Modbus ASCII 

    • Modbus Functions: Master – commands 1, 2, 3, 4, 5, 6, 15, 16, 22, 23; Slave – commands 1, 2, 3, 4, 5, 6, 15, 16, 17, 22 

    • Data Memory: 5000-word register space for processor-to-network data exchange 

    • Backplane Current: 800 mA @ 5.1 Vdc 

    • Operating Temperature: 0 to 60°C (32 to 140°F) 

    • Configuration: Via RSLogix 5000 with sample ladder logic provided; Add-On Instructions available for version 16 and above 

    Related Product Recommendations

     
     
    Category Model Key Features
    Enhanced Replacement MVI56E-MCM Enhanced version with direct backward compatibility and larger 10,000-word database; drops-in replacement for MVI56-MCM 
    CompactLogix Alternative ILX56-MM InRail series upgrade for CompactLogix platforms; modern hardware architecture; recommended as MVI56-MCM successor for CompactLogix systems 
    Third-Party Gateway EG-EIP2MB Ethernet/IP to Modbus gateway; connects via Ethernet, no programming required; alternative to in-chassis modules 

    Payment & Delivery

    FAQs

    Q1: What Modbus protocols does the MVI56-MCM support?
    It supports both Modbus RTU (binary with CRC-16) and Modbus ASCII (with LRC error checking) protocols. Each port can be independently configured for either protocol .

    Q2: Can the two ports operate as Master and Slave simultaneously?
    Yes. Each of the two application ports can be independently configured as a Modbus master, a Modbus slave, or any combination thereof .

    Q3: What is the difference between MVI56-MCM and MVI56-MCMR?
    The MVI56-MCM is the general-purpose Modbus serial solution for ControlLogix and is the preferred choice for local or remote chassis installations. The MVI56-MCMR is a variant with different specifications .

    Q4: Can the MVI56E-MCM directly replace the MVI56-MCM?
    Yes. The MVI56E-MCM is designed as an enhanced, backward-compatible replacement. It offers a larger database capacity (10,000 words vs. 5,000) and can be swapped in without controller program changes .

    Q5: What is the data exchange capacity between the module and the processor?
    The module provides a 5000-word register space for data exchange between the ControlLogix processor and the Modbus network. Data transfer is asynchronous from network activity.