New Original PROSOFT MVI56E-MNETC Enhanced Modbus TCP/IP Multi-Client/Server Communication Module

The ProSoft MVI56E-MNETC is an Enhanced Modbus TCP/IP Multi-Client/Server Communication Module for Rockwell Automation ControlLogix platforms. It enables the ControlLogix processor to communicate with multiple Modbus TCP/IP server devices.

 

  • Item No :

    MVI56E-MNETC
  • Order(MOQ) :

    1 Piece
  • Payment :

    EXW
  • Product Origin :

    USA
  • Shipping Port :

    Wuhan
  • Lead Time :

    3-5days
  • Weight :

    5KG
  • Product Details

     
     
    Specification Description
    Manufacturer ProSoft Technology
    Model MVI56E-MNETC
    Product Family MVI56E Enhanced Series
    Product Type Modbus TCP/IP Multi-Client/Server Communication Module
    Compatibility Rockwell Automation ControlLogix (1756 backplane)
    Backplane Current Load 800 mA @ 5 VDC; 3 mA @ 24 VDC 
    Ethernet Port 10/100 Mbps, auto-crossover detection 
    Modbus TCP/IP Client Up to 30 client connections, 480 Modbus commands 
    Modbus TCP/IP Server Up to 20 server connections (Service Port 502 and 2000) 
    User Database Up to 10,000 16-bit registers (Revision 3 firmware) 
    Configuration Software ProSoft Configuration Builder (PCB); RSLogix 5000 Add-On Instruction 
    LED Display 4-character scrolling alphanumeric display 
    Operating Temperature 0°C to +60°C (32°F to 140°F) 
    Storage Temperature -40°C to +85°C (-40°F to 185°F) 
    Relative Humidity 5% to 95% (non-condensing) 
    Shock 30 G operating; 50 G non-operating 
    Vibration 5 G from 10 Hz to 150 Hz 
    Warranty 3 years 

    Related Product Model Recommendations

     
     
    Model Description Typical Application
    MVI56E-MNETC (this model) Modbus TCP/IP Multi-Client/Server, 30 clients, 20 servers ControlLogix connectivity to multiple Modbus TCP/IP devices
    MVI56E-MNETCXT Extreme environment version (Logix-XT), -25°C to +70°C, conformal coated Harsh or corrosive environments 
    MVI56E-MNETCR Modbus TCP/IP Multi-Client with reduced data block Remote rack installations over ControlNet/EtherNet/IP 
    MVI56E-MNET Modbus TCP/IP Client/Server (combined client and server) Standard Modbus TCP/IP communication 
    MVI56E-MNETXT Extreme environment version of MVI56E-MNET Logix-XT platforms 
    MVI56E-MCM Modbus Master/Slave serial module Modbus RTU/ASCII serial devices

    Payment & Delivery

    FAQs

    Q1: What is the primary function of the MVI56E-MNETC?

    It is a Modbus TCP/IP communication module that allows Rockwell Automation ControlLogix processors to communicate with multiple Modbus TCP/IP server devices (such as Modicon PACs) and to act as a Modbus TCP/IP server for SCADA/DCS systems. It acts as an I/O module on the ControlLogix backplane, making Modbus data appear as standard I/O data to the processor .

    Q2: How many Modbus TCP/IP connections does the MVI56E-MNETC support?

    With Revision 3 firmware, the module supports up to 30 client connections (with 480 Modbus master commands) and up to 20 server connections . This allows the module to communicate with multiple server devices while simultaneously serving data to SCADA, HMI, or DCS systems .

    Q3: What is the difference between the MVI56E-MNETC and the MVI56E-MNET?

    The MVI56E-MNETC is a Multi-Client module optimized for applications where the ControlLogix system needs to control multiple Modbus TCP/IP server devices on the network. The MVI56E-MNET is a combined client/server module for standard Modbus TCP/IP communication. With Revision 3 firmware, the MNETC now also supports server functionality, making it the recommended choice for most applications .

    Q4: Does the MVI56E-MNETC require additional programming in RSLogix 5000?

    No additional complex programming is required. The module communication is integrated into RSLogix 5000 using a provided Add-On Instruction (AOI) or ladder logic sample file. The AOI handles data transfer between the module and the processor, and commands can be easily enabled or disabled from ladder logic without reconfiguring the module .

    Q5: Is the MVI56E-MNETC backward compatible with older MVI56-MNETC modules?

    Yes. The MVI56E-MNETC is backward compatible with earlier MVI56-MNETC modules. You can transfer the configuration from the old module to the new one by moving the CF card, and the existing ladder logic will continue to work. To take advantage of new features like the expanded 10,000-register database, the latest Add-On Instruction must be used.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.