New Original PROSOFT PLX31-EIP-MBTCP DIN-rail Mounted Communication Gateway

The ProSoft PLX31-EIP-MBTCP is a stand-alone DIN-rail mounted communication gateway that enables high-speed bi-directional data transfers between EtherNet/IP and Modbus TCP/IP networks. It allows Rockwell Automation controllers (ControlLogix, CompactLogix, PLC-5, SLC) to communicate seamlessly with Modbus TCP/IP devices and vice versa, eliminating the need for complex custom programming.

  • Item No :

    PLX31-EIP-MBTCP
  • Order(MOQ) :

    1 Piece
  • Payment :

    EXW
  • Product Origin :

    USA
  • Shipping Port :

    Wuhan
  • Lead Time :

    3-5days
  • Weight :

    5KG
  • Product Details

     
     
    Specification Description
    Manufacturer ProSoft Technology
    Model PLX31-EIP-MBTCP
    Product Family PLX30 Series
    Product Type EtherNet/IP to Modbus TCP/IP Communication Gateway
    Mounting DIN-rail (stand-alone)
    EtherNet/IP Server Connections 5 (Class 3)
    EtherNet/IP Client Connections 2 connected + 1 unconnected (Class 3)
    EtherNet/IP I/O Connections 2 (Class 1)
    I/O Connection Size 248/248 bytes
    Max RPI Time 5 ms per connection
    Supported PLC Types PLC2, PLC5, SLC, CLX, CMPLX, MICROLX
    Modbus TCP/IP Clients Supported 10
    Modbus TCP/IP Servers Supported MBAP: 5; Encapsulated: 5
    Modbus Client Commands Up to 160 fully configurable commands
    Data Registers Up to 10,000 x 16-bit registers
    Power Supply 24 VDC nominal (10 to 36 VDC allowed)
    Current Load 300 mA @ 24 VDC nominal; 610 mA max @ 10-36 VDC
    Operating Temperature -25°C to +70°C
    Storage Temperature -40°C to +80°C
    Dimensions (H x W x D) 13.67 x 5.05 x 11.13 cm
    Configuration Software ProSoft Configuration Builder (PCB); embedded EDS Add-On Profile
    SD Card Slot Yes (SD card optional, for config backup/disaster recovery)
    Security Module switch for configuration security (v1.04+)
    Certifications ODVA Conformant
    Warranty 3 years

    Related Product Model Recommendations

     
     
    Model Description Typical Application
    PLX31-EIP-MBTCP (this model) EtherNet/IP to Modbus TCP/IP Gateway Rockwell ↔ Modbus TCP/IP integration
    PLX32-EIP-MBTCP Dual-Ethernet port version Network separation/isolation applications
    PLX31-EIP-MBS EtherNet/IP to Modbus Serial Gateway Modbus RTU/ASCII serial device integration
    PLX32-EIP-PND EtherNet/IP to PROFINET Device Gateway Rockwell ↔ Siemens cross-protocol integration
    MVI56E-MNETC Modbus TCP/IP Multi-Client/Server for ControlLogix In-chassis ControlLogix Modbus TCP/IP connectivity

    Payment & Delivery

    FAQs

    Q1: What is the primary function of the PLX31-EIP-MBTCP?

    It is a stand-alone communication gateway that enables bi-directional data transfer between EtherNet/IP controllers/devices and Modbus TCP/IP controllers/devices. It acts as a protocol converter, allowing Rockwell Automation PLCs to read/write data to Modbus TCP/IP devices and enabling Modbus TCP/IP masters to access data from Rockwell controllers.

    Q2: What PLC types are supported by this gateway?

    The gateway supports PLC2, PLC5, SLC, CLX (ControlLogix), CMPLX (CompactLogix), and MICROLX for EtherNet/IP communication. It uses PCCC and CIP message types, with support for PLC-2/PLC-3/PLC5 Basic, PLC5 Binary, PLC5 ASCII, and SLC500 command sets.

    Q3: How many Modbus TCP/IP connections does the PLX31-EIP-MBTCP support?

    The gateway supports up to 10 Modbus TCP/IP clients and 5 Modbus TCP/IP servers (MBAP) simultaneously. It supports up to 160 fully configurable client commands, with individual error codes reported for each command. Supported Modbus function codes include 1, 2, 3, 4, 5, 6, 15, 16, 22, and 23 .

    Q4: Does the gateway require additional programming in RSLogix/Studio 5000?

    No complex programming is required. The gateway includes an embedded EDS Add-On Profile that simplifies integration and reduces commissioning time. Configuration is performed using ProSoft Configuration Builder (PCB) software, and the module communicates with the PLC via standard EtherNet/IP I/O or explicit messaging.

    Q5: What are the key diagnostic and data management features?

    The gateway features data prioritization (allowing different RPIs for status and control data), SD card slot for configuration backup/disaster recovery, ProSoft Discovery Service for easy IP configuration without being on the same subnet, and module switch security (v1.04+) to prevent unauthorized configuration changes.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.