Product Details
Part Number Breakdown (330730-AAA-BB-CC):
-
330730 – Base: 3300 XL 11mm extension cable
-
-040 – Length: 4.0 meters
-
-00 – Connector & Cable Option: Standard cable (no armor, no connector protector)
-
-00 – Agency Approval: Not required
Related Product Model Recommendations
| 3500/60-01-00 163179-01+133819-01 |
3500/22M 288055-01+146031-01 |
3500/92/04-01-00 136180-01 136188-02 |
330851-04-000-040-10-01-00 |
| 3500/60 133811-01 |
3500/22-01-01-00 |
3500/92-02-01-00 |
330851-000-070-10-00-05 |
| 3500/60 173186-01 |
3500/22M-01-01-00 |
3500/92-04-01-00 |
330851-02-000-030-10-00-00 |
| 3500/60 190085-01L |
3500/22M 288055-01L |
3500/92 136180-01 |
330851-02-000-030-10-00-05 |
| 133827-01 |
3500/22M 288055-01 |
3500/92 136188-01 |
330851-02-000-050-10-00-05 |
| 3500/60-05-00 |
3500/22-01-01-01 |
3500/92 136188-02 |
330851-02-000-050-50-00-05 |
| 133819-01 |
3500/22M-01-01-01 |
3500/22-02-00 |
330851-02-000-050-90-00-05 |
Payment & Delivery

FAQs

Q1: Which transducer system is the 330730-040-00-00 designed for?
This cable is specifically designed for the 3300 XL 11mm Proximity Transducer System. It is not compatible with the 8mm system (330130 series) without proper system matching.
Q2: What is the difference between the 330730-040-00-00 and the 330130 series extension cables?
The 330730 series is designed for the 11mm probe system, which provides a larger linear measurement range (4mm vs. 2mm) for applications such as axial thrust position and differential expansion. The 330130 series is for the 8mm system, used primarily for radial vibration measurement.
Q3: What do the "-00" suffixes in the part number mean?
The first "-00" indicates standard cable (no armor, no FluidLoc, no connector protector). The second "-00" indicates no agency approvals required. For hazardous areas, use the "-05" suffix.
Q4: What is the recommended minimum bend radius for this cable?
The minimum bend radius is 25.4 mm (1.0 inch) to prevent cable kinking and maintain signal integrity.
Q5: What are the temperature limitations for the 330730-040-00-00?
The operating temperature range is –40°C to +85°C. However, prolonged exposure below –34°C may cause the seal to degrade prematurely, so avoid exposing the cable to extreme cold during shipping or storage.