Product Details
Part Number Breakdown (330103-08-13-10-02-00) :
-
330103 – Base: 3300 XL 8mm Probe, M10×1 thread, unarmored
-
-08 – Unthreaded Length: 8 mm
-
-13 – Overall Case Length: 130 mm
-
-10 – Total Cable Length: 1.0 meter
-
-02 – Connector Type: Standard cable, miniature coaxial ClickLoc™
-
-00 – Agency Approval: None required
Related Product Model Recommendations
| 21000-16-05-00-019-03-02 |
21000-16-10-00-045-04-02 |
21000-28-05-15-012-04-02 |
| 21000-16-05-00-030-04-02 |
21000-16-10-00-053-03-02 |
21000-28-05-15-028-04-02 |
| 21000-16-05-00-038-04-02 |
21000-16-10-00-067-04-02 |
21000-28-05-15-50-03-02 |
| 21000-16-05-00-039-03-02 |
21000-16-10-00-095-04-02 |
21000-28-10-00-041-04-02 |
| 21000-16-05-00-040-03-02 |
21000-16-10-00-098-04-02 |
21000-16-10-15-071-03-02 |
| 21000-16-05-00-043-03-02 |
21000-16-10-00-120-03-02 |
21000-16-10-15-075-03-02 |
| 21000-16-05-00-043-04-02 |
21000-16-10-00-244-04-02 |
21000-16-10-15-102-03-02 |
| 21000-16-05-00-050-03-02 |
21000-16-10-00-256-13-02 |
21000-16-05-00-066-03-02 |
Payment & Delivery

FAQs

Q1: What is the primary application for the 330103-08-13-10-02-00 probe?
It is an eddy‑current proximity probe used for non‑contact measurement of vibration and shaft position on rotating machinery, including steam turbines, compressors, and pumps. It outputs a voltage proportional to the gap between the probe tip and the target shaft, enabling real‑time radial vibration and axial thrust monitoring .
Q2: What do the different segments in the part number mean?
Each segment defines a specific configuration: 330103 = 8mm metric probe (M10×1, unarmored); -08 = 8mm unthreaded length; -13 = 130mm case length; -10 = 1.0m cable; -02 = ClickLoc connector with standard cable; -00 = no agency approvals .
Q3: Is this probe compatible with other 3300 XL system components?
Yes. All 3300 XL 8mm components are designed for full interchangeability. Probes, extension cables, and Proximitor sensors can be mixed and matched without bench calibration, provided the total electrical lengths match — the probe cable length plus extension cable length must equal the Proximitor’s rated system length .
Q4: What is the recommended installation gap and corresponding voltage?
The optimal gap is 1.27 mm (50 mils) , which yields an output voltage of approximately -9.0 VDC at the Proximitor . The linear operating range spans -1 VDC to -17 VDC .
Q5: What are the temperature limitations for this probe?
The probe tip operates from -51°C to +177°C, while the cable withstands up to +260°C . Important: Exposing the probe to temperatures below -34°C may cause premature failure of the Viton® pressure seal.