Product Details
Part Number Breakdown (330101-00-20-10-11-00):
-
330101 – Base: 3300 XL 8 mm probe, 3/8-24 UNF thread, unarmored
-
-00 – Unthreaded Length: 0.0 in (fully threaded)
-
-20 – Overall Case Length: 2.0 in
-
-10 – Total Cable Length: 1.0 meter
-
-11 – Connector & Cable Type: ClickLoc connector with protector, FluidLoc cable
-
-00 – Agency Approval: Not required
Related Product Model Recommendations
Payment & Delivery

FAQs

Q1: What is the primary function of the 330101-00-20-10-11-00 probe?
It is an eddy‑current proximity probe used for non‑contact measurement of shaft vibration and position on rotating machinery such as turbines, compressors, and pumps. It outputs a voltage proportional to the gap between the probe tip and the shaft surface, enabling real‑time radial vibration and axial thrust monitoring .
Q2: What do the part number segments -11 and -00 mean in 330101-00-20-10-11-00?
The -11 indicates a miniature coaxial ClickLoc™ connector with an integrated connector protector and FluidLoc cable technology. The -00 indicates no agency approvals are required for general‑purpose environments .
Q3: What is the FluidLoc cable option and why is it important?
FluidLoc is a cable design that seals the inner core of the coaxial cable to prevent lubricating oil or process gas from migrating along the cable path into the connector or Proximitor sensor. This is critical in pressurized bearing applications where oil wicking could otherwise cause measurement drift or sensor failure .
Q4: What is the recommended installation gap and corresponding voltage?
The optimal gap is 1.27 mm (50 mils), which yields an output voltage of approximately -9.0 VDC at the Proximitor. The linear operating range spans approximately -1 VDC to -17 VDC .
Q5: How do I ensure compatibility with extension cables and Proximitor sensors?
The total electrical length of the probe cable plus extension cable must equal the rated system length of the Proximitor sensor (e.g., a 1.0m probe + 8.0m extension requires a 9.0m Proximitor). Mismatched components can cause measurement errors of 20% or greater . All 3300 XL 8 mm system components are designed for full interchangeability without individual matched calibration.