Product Details
Part Number Breakdown (330101-00-20-90-02-05):
-
330101 – Base: 3300 XL 8 mm probe, 3/8-24 UNF thread, unarmored
-
-00 – Unthreaded Length: 0.0 in (fully threaded)
-
-20 – Overall Case Length: 2.0 in
-
-90 – Total Cable Length: 9.0 meters
-
-02 – Connector Type: Miniature coaxial ClickLoc™ connector, standard cable
-
-05 – Agency Approval: CSA, ATEX, IECEx (multi‑approval)
Related Product Model Recommendations
Payment & Delivery

FAQs

Q1: What is the primary function of this probe?
It is an eddy‑current proximity probe used for non‑contact measurement of shaft vibration and position on rotating machinery. The 330101-00-20-90-02-05 is specifically configured for long‑distance cable runs (9.0m) and hazardous area installations with CSA/ATEX/IECEx certifications .
Q2: What is the significance of the 9.0m cable length in the part number?
The -90 option indicates a 9.0‑meter integral cable. This long cable allows flexible routing from the measurement point to the monitoring system while minimizing the need for additional extension cables. Important: A 9.0m probe requires a 9.0m Proximitor sensor (e.g., 330180-90-00)—using a mismatched length will cause measurement errors of 20% or greater .
Q3: What do the "-05" approvals mean for this probe?
The -05 suffix indicates multi‑hazardous area certifications, specifically CSA, ATEX, and IECEx. This makes the probe suitable for installation in potentially explosive environments such as oil & gas facilities and petrochemical plants .
Q4: What is the recommended installation gap and corresponding voltage?
The optimal gap is 1.27 mm (50 mils), which yields an output voltage of approximately -9.0 VDC at the Proximitor. The linear operating range spans approximately -1 VDC to -17 VDC .
Q5: Is this probe interchangeable with other 3300 XL components?
Yes. All 3300 XL 8 mm system components are designed for full interchangeability. Probes, extension cables, and Proximitor sensors can be mixed and matched without bench calibration, provided the total electrical lengths match — the probe cable length plus extension cable length must equal the Proximitor's rated system length.