New Original Stock Honeywell 900C72R-0100-43 C70R Redundant CPU Controller Module

The Honeywell 900C72R-0100-43 is a C70R Redundant CPU Controller Module for the ControlEdge HC900 hybrid control system. It serves as the central processing unit for redundant controller architectures, executing process logic, sequence control, and loop management.

  • Item No :

    900C72R-0100-43
  • Order(MOQ) :

    1 Piece
  • Payment :

    EXW/CIF
  • Product Origin :

    USA
  • Shipping Port :

    Wuhan
  • Lead Time :

    3-5days
  • Weight :

    3kg
  • Product Details

     
     
    Item Specification
    Product Type Redundant CPU Controller Module
    Manufacturer Honeywell
    Model 900C72R-0100-43
    Series ControlEdge HC900
    CPU Class C70R
    Processor Architecture 32-bit RISC PowerPC
    Memory Battery-backed DDR2 RAM with ECC
    Redundant Configuration Dual CPU with RSM-based failover management
    Communication Ports Dual 10/100 Base-T Ethernet
    Serial Communication RS-232 / RS-485 Modbus RTU
    Diagnostics Watchdog timer, firmware diagnostics, hardware self-test
    Status Indicators Front panel LEDs (power, status, mode, redundancy state)
    Operating Temperature 0°C to +60°C
    Storage Temperature -40°C to +85°C
    Relative Humidity 5% to 95% RH, non-condensing
    Weight Approx. 0.2–0.4 kg
    Country of Origin USA

    Related Product Model Recommendations

     
     
    Model Product Type Application Scenario
    900C72R-0100-44 C70R Redundant CPU (alternate revision) Same C70R class; verify firmware compatibility before pairing
    900C72R-0000-42 C70R Redundant CPU (earlier revision) Legacy redundant HC900 systems
    900RR0-0001 Redundant CPU Rack Required for dual-CPU redundant configuration
    900RSM-0001 Redundant Switch Module Manages failover between primary and backup CPUs

    FAQs

    Q1: Does the 900C72R-0100-43 support redundant controller operation?
    A: Yes. The module supports dual CPU redundant configurations with failover management through the HC900 redundant system architecture. It requires a 900RR0-0001 redundant CPU rack and a 900RSM-0001 redundant switch module for complete redundancy functionality.

    Q2: What is the difference between the -43 and -44 revisions?
    A: The 900C72R-0100-43 and 900C72R-0100-44 are different hardware revisions of the same C70R CPU class. They share the same functional role but may have firmware or minor hardware differences. For redundant CPU pairs, both modules should match exactly in revision and firmware build.

    Q3: What communication interfaces does this module provide?
    A: It features dual 10/100 Base-T Ethernet ports for network redundancy and host communication, plus RS-232 / RS-485 serial interfaces supporting Modbus RTU protocol.

    Q4: Can the CPU module be replaced while the system remains operational?
    A: Hot-swap capability depends on the complete HC900 rack configuration. In properly configured redundant setups, the standby CPU can be replaced while the primary continues running. Always follow Honeywell system maintenance documentation and ESD precautions.

    Q5: How does failover work between redundant CPUs?
    A: Dual dedicated redundancy links continuously synchronize state memory and database information between the primary and backup CPUs. If the primary detects a fault, the backup assumes complete execution control within a single scan cycle without process disruption.