New Original Bently Nevada 330780-50-00 Proximity Sensor in Stock

The Bently Nevada 330780-50-00 is a 5.0-meter Proximitor® Sensor for the 3300 XL 11 mm Proximity Transducer System. It receives signals from a 3300 XL 11 mm probe and its extension cable, conditioning them into a linear voltage output proportional to shaft displacement for radial vibration, axial thrust position, and Keyphasor measurement.

  • Item No :

    330780-50-00
  • Order(MOQ) :

    1 Piece
  • Payment :

    EXW
  • Product Origin :

    USA
  • Shipping Port :

    Wuhan
  • Lead Time :

    3-5days
  • Weight :

    3kg
  • Product Details

     
     
    Specification Description
    Manufacturer Bently Nevada (Baker Hughes)
    Model 330780-50-00
    Product Family 3300 XL 11 mm Proximity Transducer System
    Product Type Proximitor® Sensor (Signal Conditioner)
    System Length 5.0 meters (16.4 feet) 
    Mounting Type Panel Mount 
    Agency Approval Not required (00 option) 
    Input Compatibility 3300 XL 11 mm probes and extension cables only 
    Sensitivity 3.94 V/mm (100 mV/mil) nominal 
    Linear Measurement Range 4.0 mm (160 mils) 
    Recommended Gap 0.5 mm to 4.5 mm (20 to 180 mils) 
    Output Signal -24 VDC to 0 VDC proportional output 
    Power Supply (without barriers) -17.5 VDC to -26 VDC 
    Power Supply (with barriers) -23 VDC to -26 VDC 
    Max Current Consumption 12 mA 
    Output Resistance 50 Ω 
    Frequency Response 0 to 8 kHz (typical); 0 to 10 kHz per some sources 
    Operating Temperature -35°C to +85°C (sensor); -52°C to +100°C per some sources 
    Housing Material A380 Aluminum 
    Weight 255 g (9 oz) 
    Compliance API 670 compliant 
    Country of Origin USA 

    Part Number Breakdown (330780-AXX-BXX):

    • 330780 – 3300 XL 11 mm Proximitor Sensor

    • -50 – 5.0 m system length, panel mount 

    • -00 – Agency approval: Not required 


    Related Product Model Recommendations

     
     
    Model Description Typical Application
    330780-50-00 (this model) 5.0 m system, panel mount, no approvals Standard 5 m system, general purpose 
    330780-51-00 5.0 m system, DIN-rail mount, no approvals DIN-rail installations 
    330780-90-00 9.0 m system, panel mount, no approvals Longer cable runs 
    330780-91-00 9.0 m system, DIN-rail mount, no approvals DIN-rail with longer cable runs 
    330780-50-05 5.0 m system, panel mount, multiple agency approvals ATEX/IECEx hazardous areas 
    330780-50-CN 5.0 m system, panel mount, China approval Chinese market installations 
    330730-040-00-00 4.0 m extension cable Extending probe cable to match 5 m system
    330703-000-060-10-02-00 11 mm probe, 60 mm case, 1.0 m cable Typical companion probe for this sensor 
    330180-50-00 3300 XL 8 mm Proximitor Sensor Not compatible – different probe diameter 

    Payment & Delivery

    FAQs

    Q1: What is the primary function of the 330780-50-00?

    It is a Proximitor Sensor (signal conditioner) that receives the eddy-current signal from a 3300 XL 11 mm proximity probe, processes it, and outputs a linear voltage proportional to shaft displacement. This enables non-contact measurement of radial vibration, axial thrust position, and Keyphasor reference signals on large rotating machinery .

    Q2: What is the difference between the 11 mm and 8 mm Proximitor systems?

    The 11 mm system has a larger tip diameter and double the linear range (4.0 mm vs. 2.0 mm). Its output sensitivity is 3.94 V/mm (100 mV/mil), compared to 7.87 V/mm (200 mV/mil) for the 8 mm system. The 11 mm system is preferred for large shaft applications where greater measurement span is required, such as axial thrust and differential expansion monitoring .

    Q3: What mounting options are available for this sensor?

    The -50 suffix indicates panel mounting (4-hole). For DIN-rail mounting, the -51 variant (330780-51-00) is required. The two are not mechanically interchangeable .

    Q4: Can I use this sensor with an 8 mm probe?

    No. The 330780-50-00 is designed exclusively for 3300 XL 11 mm probes. Mixing it with 8 mm probes (330180 series) will result in incompatible sensitivity and linear range, leading to incorrect measurements. The entire transducer chain (probe, extension cable, and Proximitor) must be from the 11 mm system family .

    Q5: What should I check if the sensor output is unstable or inaccurate?

    Common causes of signal instability include:

    • System length mismatch – the total electrical length of the probe plus extension cable must exactly equal 5.0 meters for this model 

    • Improper grounding – the sensor should be floating (isolated from earth) to prevent ground loops 

    • High-frequency connector interference – ensure the coaxial connector is properly isolated and not in contact with the cabinet or earth 

    • Cable damage or kinking – avoid sharp bends; minimum bend radius is 25.4 mm (1.0 in)

Leave A Message