Bently Nevada 3500/62 136294-01 Process Variable Monitor

The Bently Nevada 3500/62 136294-01 is a 6-channel Process Variable I/O module designed for the 3500 Series Machinery Protection System. Its core function is to serve as a critical analog bridge, converting measurements of essential process parameters—such as pressure, flow, temperature, and level—into a format that can be monitored by the 3500 rack. This module conditions 4-20 mA current or ±10V voltage signals from field transmitters and compares them against user-programmable alarms, ensuring the safe operation of rotating machinery.

  • Item No :

    3500/62 136294-01
  • Order(MOQ) :

    1
  • Payment :

    EXW
  • Product Origin :

    USA
  • Shipping Port :

    Wuhan, Hubei, China
  • Lead Time :

    3-5 days
  • Weight :

    0.55kg
  • Product Showroom

    Bently Nevada 3500/62 136294-01

    New and Original

    More details

    Country of origin

    USA

    Product condition

    New

    Warranty

    one year

    Payment Method

    T/T, Western Union

    Shipping Method

    DHL/FedEX/UPS/TNE/EMS

    Main Specifications

    Item Specifications / Features 
    Number of Channels 6 independent analog input channels
    Input Signal Types 4 to 20 mA current; -10 to +10 Vdc voltage
    I/O Module Type Isolated I/O Module with internal terminations
    System Platform Bently Nevada 3500 Series Machinery Protection System
    Alarm Setpoints User-programmable Alert and Danger setpoints
    Power Consumption 7.0 Watts typical
    Communication OK, TX/RX, and Bypass status LEDs
    Operating Temperature -30°C to +65°C

    Core Features & Advantages

    • Versatile Signal Compatibility: A key advantage of this module is its ability to accept two of the most common industrial analog signal types: 4-20 mA current and -10 to +10V voltage . This flexibility allows it to connect to a wide variety of pressure, flow, and temperature transmitters without needing extra signal conditioners.

    • User-Programmable Alarm Logic: The module continuously compares the live input signal against user-defined "Alert" and "Danger" setpoints . This programmability is critical for fine-tuning machine protection thresholds to the specific operating envelope of a turbine or compressor.

    • High-Density 6-Channel Design: By consolidating six process variable inputs into a single full-height rack slot, the 3500/62 offers significant space savings . This makes it a far more efficient solution for monitoring auxiliary parameters compared to using separate single-channel transmitters.

    • Support for TMR Configurations: For the highest level of availability, the module can be used in Triple Modular Redundant (TMR) configurations . Three modules are grouped together to provide a reliable measurement that avoids a single point of failure.

    Typical Applications

    The 3500/62 is a standard component for monitoring critical process parameters in the 3500 system across a wide range of heavy industries:

    • Oil & Gas: Monitoring suction and discharge pressure on centrifugal compressors.

    • Power Generation: Measuring steam pressure and flow on a turbine control system.

    • General Industry: Monitoring coolant flow, tank levels, and lubrication pressures.

    Frequently Asked Questions (FAQ)

    Q1: What is the difference between the 136294-01 I/O module and the 3500/62 monitor?

    A: The 3500/62 is the overall 6-channel process variable monitor, which consists of a monitor module and a corresponding I/O module. The 136294-01 is the specific I/O module designed for use with the 3500/62 .

    Q2: Does this module support intrinsically safe (IS) sensors?

    A: The 136294-01 itself is an isolated I/O module. For direct connection of sensors in hazardous areas, you should use the variant of the 3500/62 that comes with the Internal Barrier I/O Module, which provides the necessary zener barriers and power .

    Q3: What is the maximum number of 136294-01 modules I can install in a single rack?

    A: The number you can install is limited by the rack's power supply capacity and physical slots. As a 6-channel monitor, it efficiently consolidates signals, but it is always advisable to verify power consumption against the available budget of your 3500 rack.

    Q4: Can I replace the 136294-01 while the system is running?

    A: Yes, the I/O module supports hot-swapping . However, you should always notify the control room before replacement, as the DCS will temporarily lose the analog signal from those channels during the swap.

    Q5: What do the front panel LEDs indicate?

    A: The module features three front-panel LEDs: OK indicates the monitor is in good working order; TX/RX indicates communication with the rack; and Bypass indicates the module is in a bypass mode .

    Recommended Models

    The Bently Nevada 3500/62 system consists of different components. Below are key related models:

     
     
    Product/Model Type Brief Description
    136294-01 Featured I/O Module Isolated I/O Module with internal terminations for the 3500/62 process variable monitor .
    3500/62 Monitor Main Monitor The 6-channel process variable monitor that houses the I/O module .
    136483-01 Alternative I/O Module Isolated 4-20 mA I/O module with external terminations (requires a separate termination block) .

     

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.