Bently Nevada 3500/61 Temperature Monitor

The Bently Nevada 3500/61 is a high-performance 6-channel temperature monitoring module designed for the 3500 Machinery Protection System. This module provides continuous, real-time temperature monitoring for critical rotating machinery, accepting inputs from both Resistance Temperature Detectors (RTDs) and Thermocouples (TCs) .

The 3500/61 conditions these temperature signals and compares them against user-programmable alarm setpoints. Its key distinguishing feature is the provision of recorder outputs for each of its six channels , making it the preferred choice for applications requiring analog output for trend recording or DCS integration.

  • Item No :

    3500/61
  • Order(MOQ) :

    1
  • Payment :

    EXW
  • Product Origin :

    USA
  • Shipping Port :

    Wuhan, Hubei, China
  • Lead Time :

    3-5 days
  • Weight :

    2kg
  • Product Showroom

    Bently Nevada 3500/61 Temperature Monitor

    6-Channel Temperature Monitoring Module for 3500 Machinery Protection Systems

    New and Original

    More details

    Country of origin

    USA

    Product condition

    New

    Warranty

    one year

    Payment Method

    T/T, Western Union

    Shipping Method

    DHL/FedEX/UPS/TNE/EMS

    Key Features & Benefits

    • 6 Independent Temperature Channels: Monitor up to six temperature points simultaneously from a single module, maximizing rack efficiency 

    • Dual Sensor Support: Accepts both RTD (3-wire and 4-wire platinum, nickel, copper) and Thermocouple (Types E, J, K, T) inputs, providing exceptional flexibility for diverse applications 

    • Built-in Recorder Outputs: Each channel provides dedicated 4-20 mA recorder outputs for integration with chart recorders, DCS, or PLC systems 

    • User-Programmable Alarm Setpoints: Fully configurable Alert and Danger setpoints per channel using 3500 Rack Configuration Software 

    • Flexible I/O Module Options: Available in RTD/TC non-isolated and TC isolated versions; non-isolated version supports mixing of RTD and TC inputs on the same module 

    • Channel-to-Channel Isolation (TC Isolated Version): Provides 250 VDC isolation to protect against external interference and ground loops 

    • SIL 2 Certified for Safety Applications: Certified for use in safety-related applications up to SIL 2 per IEC 61508, suitable for critical machinery protection 

    • High Input Impedance: Greater than 10 MΩ for each lead input ensures minimal loading on field sensors 

    • Hazardous Area Approvals: Certified for Class I, Division 2 and Zone 2 hazardous locations 

    • Triple Modular Redundant (TMR) Support: Configurable for TMR applications with voting logic to prevent single-point failures 

    Technical Specifications

     
     
    Category Specification
    Manufacturer Bently Nevada (Baker Hughes)
    Model Number 3500/61
    Product Type Temperature Monitor
    Channels 6 independent channels
    Input Types RTD (3-wire, 4-wire) and Thermocouple (E, J, K, T)
    Input Impedance >10 MΩ per lead 
    Recorder Outputs 4-20 mA per channel 
    Power Consumption 9 Watts typical 
    Operating Temperature -30°C to +65°C (with Internal/External Termination I/O) 
    Storage Temperature -40°C to +85°C 
    Main Module Dimensions 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in) 
    Main Module Weight 0.91 kg (2.0 lb) 
    Rack Space 1 full-height front slot + 1 full-height rear slot (I/O module) 
    Safety Certification SIL 2 (IEC 61508) 
    Hazardous Area Approvals Class I, Div 2; Class I, Zone 2; ATEX; IECEx 
    Country of Origin USA

    Supported Sensor Types

    Thermocouple (TC) Inputs 

     
     
    Type Temperature Range
    Type E -100°C to +1000°C
    Type J -18°C to +760°C
    Type K -18°C to +1370°C
    Type T -160°C to +400°C

    RTD Inputs 

     
     
    Type Temperature Range
    100Ω Platinum (α=0.00385) -200°C to +850°C
    100Ω Platinum (α=0.00392) -200°C to +700°C
    120Ω Nickel -80°C to +260°C
    10Ω Copper -100°C to +260°C

    I/O Module Options

    The 3500/61 is configured with different I/O modules based on application requirements :

     
     
    I/O Option Description Termination
    -01 RTD/TC Non-isolated I/O Module Internal Terminations
    -02 RTD/TC Non-isolated I/O Module External Terminations
    -03 TC Isolated I/O Module Internal Terminations
    -04 TC Isolated I/O Module External Terminations
    -05 RTD/TC Non-isolated I/O Module Internal Terminations

    Key Differences:

    • RTD/TC Non-isolated: Allows mixing of RTD and TC inputs on the same module; more cost-effective 

    • TC Isolated: Provides 250 VDC channel-to-channel isolation; ideal for applications with significant ground potential differences 

    Applications

    The 3500/61 Temperature Monitor is deployed across industries requiring continuous temperature monitoring of critical rotating machinery:

     
     
    Industry Application
    Power Generation Bearing temperature monitoring on steam and gas turbines; generator winding temperature
    Oil & Gas Compressor bearing and discharge temperature monitoring; pipeline pump protection
    Chemical Processing Critical pump bearing temperature; reactor agitator monitoring
    Pulp & Paper Paper machine dryer bearing monitoring
    Mining Crusher and mill bearing temperature protection

    Typical Measurement Points:

     

    • Thrust and radial bearing temperatures

    • Oil inlet and outlet temperatures

    • Process gas/fluid temperatures

    • Motor winding temperatures

    • Exhaust gas temperatures