Beckhoff KL3172 2-Channel Analog Input Terminal

The KL3172 is a two-channel analog input terminal from the Beckhoff Bus Terminal series (KL series) for the traditional K-Bus I/O system, featuring integrated diagnostics. It measures 0–10 V voltage signals from sensors, transmitters, and other field devices, converting them to digital values for the controller, while providing diagnostic feedback on input status. It is used where unipolar voltage signals require monitoring or fault detection. Unlike EtherCAT terminals (EL series), the KL series communicates via the K-Bus and is typically used with Beckhoff Bus Couplers or Bus Terminal Controllers.

  • Item No :

    KL3172
  • Order(MOQ) :

    1
  • Payment :

    EXW
  • Product Origin :

    Germany
  • Shipping Port :

    Wuhan, Hubei, China
  • Lead Time :

    3-5 days
  • Weight :

    0.5kg
  • Overview

    Product display

    KL3172 Original New in Stock

     

     

     

     

     

     

     

     

     

     

     

     

    Parameters

     
     
    Parameter Specification
    Product Name KL3172
    Series Bus Terminal (KL Series, K-Bus)
    Function Analog input (voltage) with diagnostics
    Number of Channels 2 (analog voltage inputs)
    Input Signal 0–10 V (confirm exact range and input impedance in datasheet)
    Resolution 12 bit (typical); confirm exact resolution in datasheet
    Accuracy Confirm exact accuracy class in datasheet
    Input Impedance Confirm exact value in datasheet
    Diagnostics Integrated diagnostics (e.g., overrange/underrange, wire break where supported); confirm exact diagnostic functions in datasheet
    Conversion Time Configurable; confirm input update rates in datasheet
    Electrical Isolation 500 V (channel to bus); confirm isolation ratings in datasheet
    K-Bus Interface K-Bus (backplane of the Bus Terminal system)
    Current Consumption Typically from K-Bus; confirm exact value in datasheet
    Diagnostics Indicators Channel-wise status and diagnostic LEDs; confirm in datasheet
    Configuration Via Bus Coupler/Controller configuration (e.g., KS2000 or TwinCAT); confirm in datasheet
    Operating Temperature 0 °C … +55 °C
    Storage Temperature -25 °C … +85 °C
    Dimensions (W × H × D) 12 mm × 100 mm × 68 mm (typical KL housing)
    Weight Approx. 50 g
    Mounting DIN rail (EN 60715)
    Protection Class IP20
    Approvals CE, UL (depending on variant)

    Note: Specifications are indicative. The KL3172 is a K-Bus analog input terminal with diagnostics. Exact resolution, accuracy, input impedance, supported diagnostic functions, and update rates must be verified against the current Beckhoff datasheet for your revision. The KL series differs from the EtherCAT EL series in the bus system used.


    Core Advantages

    1. Monitored 0–10 V Input
    Combines standard 0–10 V voltage measurement with integrated diagnostics, enabling both signal acquisition and fault visibility in one terminal.

    2. Integrated Input Diagnostics
    Provides diagnostic feedback on input status and fault conditions (e.g., overrange/underrange, wire break where supported), enabling faster fault detection and reduced downtime.

    3. Two Inputs in a 12 mm Housing
    Two independent analog voltage inputs with diagnostics in a compact Bus Terminal housing, suitable for critical dual-sensor acquisition in K-Bus systems.

    4. Standard 0–10 V Interface
    Measures the widely used 0–10 V signal, compatible with a broad range of sensors, transmitters, and analog signal sources.

    5. Per-Channel Configuration
    Measurement scaling and filter settings are configurable per channel through the Bus Coupler/Controller. Confirm the exact configuration options in the datasheet.

    6. K-Bus System Integration
    Integrates into the Beckhoff Bus Terminal system via the K-Bus, working with Bus Couplers and Bus Terminal Controllers for fieldbus connectivity.

    7. Channel-Wise Status and Diagnostic LEDs
    LEDs per channel indicate input state and diagnostic conditions, supporting fast commissioning and troubleshooting.

    Applications

    • Monitored sensor acquisition — 0–10 V pressure, flow, level, and position transmitters requiring fault feedback.

    • Machine building — analog signal acquisition with diagnostics in motion, clamping, and process control.

    • Process technology — measurement of standard analog process signals with fault detection.

    • Legacy K-Bus systems — expansion and maintenance with diagnostic capability.

    • OEM equipment — embedded diagnostic analog input in industrial machines.

    • Test benches — analog signal acquisition with monitoring in validation and R&D rigs.

    • Building automation — 0–10 V sensor acquisition with diagnostics for HVAC and energy systems.

    FAQ

    Q1: What is the KL3172 used for?
    It is a 2-channel analog input terminal with integrated diagnostics for the Beckhoff K-Bus Bus Terminal system, used to measure 0–10 V voltage signals from sensors and transmitters with fault feedback.

    Q2: What is the difference between KL3062 and KL3172?
    Both are 2-channel 0–10 V analog input terminals for the K-Bus system; the KL3172 adds integrated diagnostics for input status monitoring. Confirm the exact differences in the current datasheet.

    Q3: What is the difference between KL3162 and KL3172?
    The KL3162 measures bipolar ±10 V with 16-bit resolution and diagnostics; the KL3172 measures unipolar 0–10 V with diagnostics. Choose based on signal polarity and resolution requirements.

    Q4: What diagnostic functions are supported?
    Diagnostics may include overrange, underrange, and wire break (where supported) detection depending on configuration. Confirm the exact supported diagnostic functions in the current datasheet.

    Q5: What resolution does it provide?
    Typically 12-bit resolution, but the exact resolution must be confirmed in the current datasheet.

    Q6: How is the terminal configured?
    Configuration is performed through the Bus Coupler or Bus Terminal Controller (e.g., via KS2000 or TwinCAT). Confirm the exact workflow in the datasheet.

    Q7: Does it require an external 24 V supply?
    The terminal logic is powered from the K-Bus; the analog input stage may require a field supply depending on the variant. Confirm the exact supply requirements in the datasheet.

    Q8: Is the KL3172 suitable for safety functions?
    No. It is a standard automation terminal and is not a certified safety component. Use appropriately certified hardware for safety-related signal acquisition.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.