The Allen-Bradley 2080-L50E-24AWB is a Micro850 programmable logic controller (PLC) designed for larger standalone machine control applications requiring flexible communication and expanded I/O capabilities. This 24-point controller features 14 AC inputs and 10 relay outputs, with an embedded EtherNet/IP port for seamless integration into modern industrial networks.

  • Item No :

    2080-L50E-24AWB
  • Order(MOQ) :

    1 Piece
  • Payment :

    EXW
  • Product Origin :

    France
  • Shipping Port :

    Wuhan
  • Lead Time :

    3~5 days
  • Weight :

    5kg
  • Product Details

     
     
    Feature Description
    Manufacturer Allen-Bradley / Rockwell Automation
    Product Family Micro850 Programmable Logic Controller
    Catalog Number 2080-L50E-24AWB
    Inputs 14 - 120V AC inputs
    Outputs 10 relay outputs
    Input Power 24V DC
    Communication Ports Embedded EtherNet/IP port, USB programming port, non-isolated RS-232/485 serial port 
    Plug-in Slots 3 slots for functional plug-in modules
    Expansion Capability Supports up to 4 Micro850 expansion I/O modules; maximum 192 I/O points
    High-Speed Features High-speed counter (HSC) inputs on 24V DC models
    Motion Control Embedded PTO (Pulse Train Output) supports up to 3 axes of motion
    Data Storage microSD card slot for program transfer, data logging, and recipe management
    Programming Software Connected Components Workbench™ (version 20.01 or later)
    Operating Temperature -20°C to +65°C (-4°F to +149°F) 
    Dimensions (HxWxD) 90 x 158 x 80 mm (3.54 x 6.22 x 3.15 in) 
    Weight Approx. 0.2 kg (0.93 lb)

    Relay Output Ratings (2080-L50E-24AWB):

     
     
    Attribute Value
    Min. Voltage 5V DC / 5V AC
    Max. Voltage 125V DC / 265V AC
    Min. Load Current 10 mA
    Max. Load Current 2.0 A
    Max. Current per Common 5 A
    Turn On/Off Time 10 ms 

    Related Product Recommendations

     
     
    Category Model Description
    24-Point DC Input Version 2080-L50E-24QWB Similar controller with 14 DC inputs and 10 relay outputs (24V DC inputs)
    48-Point Version 2080-L50E-48AWB 48-point controller with 28 AC inputs and 20 relay outputs
    Higher-Performance 2080-L70E-24AWB Micro870 controller with larger memory and more expansion capability
    Expansion I/O 2085 Series Expansion I/O modules for adding digital/analog I/O points 
    Plug-in Module 2080-IF2 / 2080-IF4 Analog input plug-in modules for adding analog capability
    Remote LCD Display 2080-REMLCD Remote display module for IP address configuration and text display 
    2711-K10C10 2711-K10G3 2711-T10C20L1
    2711-K10C10L1 2711-K10G3L1 2711-T10C3
    2711-K10C12 2711-K10G8 2711-T10C3L1
    2711-K10C12L1 2711-K10G8L1 2711-T10G16
     2711-K10C14 2711-K10G9 2711-T10G16L1
    2711-K10C14L1  2711-K10G9L1 2711-T10G1L1
    2711-K10C15  2711-T10C1 2711-T10G20
    2711-K10C15L1 2711-T10C10 2711-T10G20L1
    2711-K10C16 2711-T10C10L1 2711-T10G3
    2711-K10C16L1 2711-T10C8 2711-T10G3L1
    2711-K10C1L1 2711-T10C8L1 2711-T10G8
    2711-K10C20 2711-T10C9 2711-T10G8L1
    2711-K10C20L 2711-T10C9L1 2711-T10G9
    2711-K10C8 2711-T10G1 2711-T10G9L1
    2711-K10C8L1 2711-T10G10 2711-B6C1
    2711-K10C9 2711-T10G10L1 2711-K10C8   
    2711-K10C9L1 2711-T10G12 2711-K10C1

    Payment & Delivery

    FAQs

    Q1: What type of inputs does the 2080-L50E-24AWB support?

    This controller has 14 AC inputs rated for 120V AC operation, making it suitable for applications with AC sensors and switches . The "A" in the catalog number indicates AC inputs.

    Q2: How many relay outputs does this controller have?

    It provides 10 relay outputs, each rated for up to 2.0 A at 125V DC or 265V AC, with a maximum of 5 A per common.

    Q3: Does this controller support EtherNet/IP communication?

    Yes, the 2080-L50E-24AWB has an embedded EtherNet/IP port for networking with other devices, HMIs, and SCADA systems.

    Q4: Can I expand the I/O beyond the built-in 24 points?

    Yes, the Micro850 supports up to four expansion I/O modules (2085 series), which can increase the total system I/O to 192 points.

    Q5: What software is required to program this controller?

    The controller is programmed using Rockwell Automation's Connected Components Workbench™ software. Version 20.01 or later is recommended for the 2080-L50E controllers.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.