ABB AO890 3BSC690072R1 Analog Output Module New in Stock

The ABB AO890 (3BSC690072R1) is an 8-channel intrinsically safe analog output module from the S800 I/O system, designed for ABB System 800xA DCS and AC 800M controllers. The module features integrated intrinsic safety (Ex ia) protection components on each channel, allowing direct connection to process equipment in hazardous areas (Zone 0/1/2) without requiring external safety barriers.

  • Item No :

    AO890 3BSC690072R1
  • Order(MOQ) :

    1 Piece
  • Payment :

    EXW
  • Product Origin :

    Sweden
  • Shipping Port :

    Wuhan
  • Lead Time :

    3-5days
  • Weight :

    3kg
  • Product Details

     
     
    Specification Description
    Manufacturer ABB
    Model AO890
    Article Number 3BSC690072R1 
    Product Family S800 I/O System
    Platform Compatibility System 800xA DCS, AC 800M controllers 
    Product Type Intrinsically Safe Analog Output Module
    Channels 8 x unipolar single-ended 
    Signal Range 0...20 mA or 4...20 mA 
    Resolution 12-bit 
    Accuracy (Error) Typ. 0.05%, Max. 0.1% at 650 Ω 
    Temperature Drift Typ. 50 ppm/°C, Max. 100 ppm/°C 
    Output Load <725 Ω at 20 mA; <625 Ω at up to 22 mA 
    Rise Time (10% to 90%) 1 ms 
    Under/Over Range 0 / 22 mA 
    Intrinsic Safety Yes – Ex ia protection on each channel 
    HART Support No 
    Redundancy Support No 
    High Integrity (SIL) No 
    Isolation Groupwise isolated from ground (8 channels as 1 group) 
    Rated Insulation Voltage 50 V 
    Dielectric Test Voltage 500 V AC 
    Power Dissipation 3.1 W 
    Current Consumption (+5V ModuleBus) 80 mA 
    Current Consumption (+24V ModuleBus) Typ. 110 mA, Max. <150 mA 
    Current Consumption (+24V External) Typ. 220 mA, Max. <300 mA 
    Diagnostic LEDs F (Fault), R (Run), W (Warning), OSP 
    Supervision Internal process supply monitoring; open wire detection if set value >1 mA 
    Operating Temperature 0°C to +55°C (vertical mounting in compact MTU: 40°C) 
    Storage Temperature -40°C to +70°C 
    Protection Class IP20 (IEC 60529) 
    Hazardous Location Certifications ATEX/IECEx Zone 2 with interface to Zone 0; cFMus C1 Div2/Zone2 with interface to C1/C2/C3 Div1/Zone0 
    Marine Certifications ABS, BV, DNV, LR 
    Corrosion Protection ISA-S71.04: G3 
    Compatible MTUs TU890 (Ex applications), TU891 (non-Ex applications) 
    Keying Code AD 
    Dimensions (W x D x H) 45 mm x 102 mm x 119 mm 
    Weight Approx. 0.20 – 0.30 kg 
    Country of Origin Sweden 

    Related Product Model Recommendations

     
     
    Model Description Typical Application
    AI890 (3BSC690073R1) 8-channel intrinsically safe analog input module Input counterpart for AO890 in hazardous area I/O sets
    AO895 (3BSC690087R1) 8-channel analog output, intrinsically safe with HART pass-through Applications requiring both intrinsic safety and HART communication
    AO845A 8-channel analog output with HART and redundancy support (non-IS) High-availability systems with redundancy requirement (non-hazardous)
    AO815 8-channel analog output with HART (non-IS, non-redundant) Standard HART output applications without intrinsic safety requirement
    TU890 / TU891 Compact MTU for AO890 Required mounting base for field wiring connection (TU890 for Ex, TU891 for non-Ex) 
    3BHB018162  3BHE024577R0101  ‌3BHE009319R0001
    3BHB003041R0101 UFC719AE01 3BHB003041R0101 3BHE020455R0001
    3BSE042238R2 PP846A 3BHE022293R0101   3BHE025088R6618
    3BSE004006R1 CI626V1 3PHE022287R0001 PHARPS3200000
    3BSE018124R1 CI853K01 PM582-ETH PHBRC3000000  
    1SFA895013R7000 PM583-ETH V18345-1010161001 
    1SFA894013R7000 PM585-ETH V18345-1017461001
    1SCA115374R1001  PM591-2ETH 2TLA020070R1800
    ASC550-01-059А-4 PM591-ETH PM867K02
    ASC550-01-0125А-4 PM592-ETH SM812
    ACS800-104LC-0700-7+E205 PM595-4ETH-F BC810
    ACS880-01-061A-3   1492-IFM40F-FS120-4 086444-005

    Payment & Delivery

    FAQs

    Q1: What is the key difference between AO890 and AO895?

    Both are intrinsically safe analog output modules with 8 channels. The AO890 does not support HART communication , while the AO895 features HART pass-through on each channel. For applications requiring HART asset management on smart field instruments in hazardous areas, choose AO895.

    Q2: Which ABB control systems is the AO890 compatible with?

    The AO890 is part of the S800 I/O system and is designed for ABB System 800xA DCS and AC 800M controllers . It can be configured and managed using the Control Builder M engineering tool.

    Q3: Can the AO890 be used with HART-enabled devices?

    No. The AO890 does not include a HART interface . It is designed purely for reliable analog current output and does not support HART pass-through communication.

    Q4: Which MTU (Module Termination Unit) should be used with the AO890?

    Use the TU890 for hazardous area (Ex) applications, and the TU891 for non-Ex applications. Both MTUs support two-wire connection to process devices.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.