New Original Honeywell FC-QPP-0002 Enhanced Performance Quad Processor Pack

The Honeywell FC-QPP-0002 is the Enhanced Performance Quad Processor Pack (QPP) for the Safety Manager (SM) and Safety Manager SC platforms within Honeywell's Experion PKS process safety system. It serves as the central processing unit and "heart" of the Safety Manager, reading field I/O signals, executing safety logic created in graphical Functional Logic Diagrams (FLDs), and driving safety outputs with hardware-level data comparison to meet strict SIL 3 requirements.

  • Item No :

    FC-QPP-0002
  • Order(MOQ) :

    1 Piece
  • Payment :

    EXW/CIF
  • Product Origin :

    USA
  • Shipping Port :

    Wuhan
  • Lead Time :

    3-5days
  • Weight :

    3kg
  • Product Details

     
     
    Specification Description
    Manufacturer Honeywell
    Model FC-QPP-0002
    Product Family Safety Manager / Safety Manager SC
    Product Type Enhanced Performance Quad Processor Pack (QPP)
    Architecture Dual synchronous processors with hardware data comparators 
    Safety Certification SIL 3 (IEC 61508), TÜV certified 
    Voting Architecture 1oo2D (non-redundant); 2oo4D (redundant configuration) 
    Diagnostic Coverage > 99% 
    24 VDC Supply 24 VDC (-15% to +30%), max 25 mA 
    5 VDC Supply 5 VDC (±5%) via backplane, max 1.2 A 
    On-Board Memory 2 × 2 MB Flash (System/App); 2 × 256 KB Battery-backed SRAM; 2 × 512 KB SRAM (Comm Link) 
    Emergency Shutdown (SD) Input 24 VDC galvanically isolated; de-energizes watchdog outputs directly 
    User Interface 8-digit diagnostic display; Up/Down scroll buttons; 3-position Key Switch (RUN/IDLE/STOP) 
    Operating Temperature -5°C to +70°C (external rack ambient) 
    Storage Temperature -40°C to +85°C 
    Relative Humidity 10% to 95%, non-condensing 
    Physical Dimensions (H × W × D) 176 mm × 88.5 mm × 212 mm 
    Unit Weight Approx. 1.30 kg (2.87 lbs) 
    Compatibility Backward compatible with QPP-0001 (requires R121 firmware or higher) 
    Lifecycle Status Active – critical spare part 

    Related Product Model Recommendations

     
     
    Model Description Typical Application
    FC-QPP-0002 (this model) Enhanced Performance Quad Processor Pack Primary safety logic solver for Safety Manager
    FC-QPP-0001 Predecessor Quad Processor Pack Legacy systems (QPP-0002 is drop-in replacement) 
    FC-QPP-0002 CC V1.0 Next-generation QPP (Safety Manager R151+) New installations requiring latest firmware 
    FC-RUSIO-3224 32-ch Universal Safety I/O Module SIS I/O for ESD, F&G, BMS 
    FC-USI-0002 Universal Safety Interface Module Non-safety communication gateway 
    FC-BKM-0001 Battery Backup Module RAM retention for QPP-0002 
    FC-SCNT01 / FC-SCNT02 Safety Manager SC Controller Module Central logic solver for SMSC platform

    FAQs

    Q1: What is the primary function of the FC-QPP-0002?

    It is the central processing unit for the Honeywell Safety Manager system. It reads field I/O signals, executes safety logic created in graphical Functional Logic Diagrams (FLDs), and transmits results to output interfaces. Continuous testing by the QPP-0002 ensures safe process control and provides extensive system and equipment diagnostics.

    Q2: What is the difference between FC-QPP-0002 and FC-QPP-0001?

    The FC-QPP-0002 is the second-generation (enhanced performance) Quad Processor Pack. It is backward compatible with the QPP-0001 and serves as a one-on-one drop-in replacement when the Safety Manager is running firmware R121 or higher.

    Q3: What is the voting architecture of the FC-QPP-0002?

    In a non-redundant Controller, one QPP-0002 module operates with 1oo2D functionality (dual processors with hardware data comparators). In a redundant Controller, two QPP-0002 modules form a 2oo4D voting architecture, providing the highest level of fault tolerance for SIL 3 applications.

    Q4: Can the FC-QPP-0002 be hot-swapped?

    Only when the key switch is in STOP position. The module can be safely removed or replaced only when the key switch is set to STOP. In redundant configurations, the replacement module synchronizes and copies the application logic across the redundant communication link. In non-redundant systems, the application file must be reloaded via Safety Builder software.

    Q5: What firmware version is required for compatibility?

    The FC-QPP-0002 requires Safety Manager firmware R121 or higher for seamless drop-in replacement of the QPP-0001. Major firmware revision mismatches can lead to communication link timeouts or FLD execution halts. Always confirm that the system software build in the Safety Builder utility matches the target processor build version.