Brand New Bently Nevada 3500/32-01-00 Relay Module in Stock

The Bently Nevada 3500/32-01-00 is a 4-Channel Relay Module for the 3500 series machinery protection system. It is a full-height module that provides four relay outputs, each independently programmable to perform voting logic. The module uses Alarm Drive Logic with AND/OR programming, allowing relays to respond to Alert, Danger, Not-OK, or individual PPL statuses from any monitor channel in the rack.

  • Item No :

    3500/32-01-00
  • Order(MOQ) :

    1 Piece
  • Payment :

    EXW/CIF
  • Product Origin :

    USA
  • Shipping Port :

    Wuhan
  • Lead Time :

    3-5days
  • Weight :

    3kg
  • Product Details

     
     
    Specification Description
    Manufacturer Bently Nevada (Baker Hughes)
    Model 3500/32-01-00
    Product Family 3500 Machinery Protection System
    Product Type 4-Channel Relay Module (Full-Height)
    Number of Relays 4 independent channels 
    Relay Type Two SPDT relays connected as DPDT per channel 
    Contact Life 100,000 cycles @ 5A, 24 Vdc or 120 Vac 
    Max Switched Current 5 A 
    Max Switched Voltage 30 Vdc / 250 Vac 
    Switched Power Capacity 120 W DC / 600 VA AC 
    Arc Suppressor 250 Vrms, standard installation 
    Sealing Epoxy-sealed relay assembly 
    Operating Mode Switch-selectable Normally Energized or Normally De-energized 
    Power Consumption 6 W typical 
    LED Indicators OK, TX/RX, CH ALARM 
    Rack Space 1 full-height front slot + 1 full-height rear I/O slot 
    Operating Temperature -30°C to +65°C 
    Storage Temperature -40°C to +85°C 
    Humidity 95%, non-condensing 
    Main Module Dimensions 241 mm x 24.4 mm x 242 mm 
    Main Module Weight 0.7 kg 
    I/O Module Dimensions 241 mm x 24.4 mm x 99.1 mm 
    I/O Module Weight 0.4 kg 
    Lifecycle Status Active / Mature

    Related Product Model Recommendations

     
     
    Model Description Typical Application
    3500/32-01-00 (this model) 4-Channel Relay Module, no agency approval Standard alarm/shutdown logic 
    3500/32-01-01 4-Channel Relay Module, CSA/NRTL/C approved North American installations requiring certification 
    3500/32-01-02 4-Channel Relay Module, ATEX/IECEx/CSA approved Hazardous area (Zone 2) installations 
    3500/32M-01-00 Enhanced 4-Channel Relay Module (SIL 2) Functional safety applications 
    3500/33 16-Channel Relay Module High-density relay output requirements 
    125712-01 Spare 4-Channel Relay Module (main card) Replacement main card for 3500/32 
    125720-01 Spare 4-Channel Relay I/O Module Replacement I/O module for 3500/32 
    125720-02 Spare 4-Channel Relay I/O Module (hazardous area/functional safety) Replacement I/O for 3500/32M applications 

    Payment & Delivery

    FAQs

    Q1: What is the primary function of the 3500/32-01-00?

    It is a 4-Channel Relay Module that provides four independent relay outputs for alarm and shutdown logic in the 3500 machinery protection system. Each output can be independently programmed to perform voting logic using Alarm Drive Logic with AND/OR combinations of Alert, Danger, Not-OK, or PPL inputs from any monitor channel in the rack .

    Q2: Where can the 3500/32-01-00 be installed in the rack?

    The module can be placed in any slot to the right of the Rack Interface Module (RIM) or Transient Data Interface (TDI). It occupies one full-height front slot and requires one full-height rear slot for the I/O module .

    Q3: What is the difference between the 3500/32 and the 3500/32M?

    The 3500/32M is the enhanced version that supports SIL 2 functional safety and ATEX/IECEx hazardous area certifications. It uses the 149986-02 main card, while the standard 3500/32 uses the 125712-01 main card. The two are not interchangeable — installing a 3500/32M card in a legacy 3500/32 rack causes functionality issues, while using a 3500/32 card in a 3500/32M rack compromises safety certifications.

    Q4: What are the common causes of channel alarm LEDs staying illuminated?

    Common causes include:

    • Relay coil failure or stuck contact: Cycle the channel's programmed logic in the configuration software and check for continuity across relay contacts.

    • Programming/voting logic misconfiguration: Re-verify the Alarm Drive Logic setup in the 3500 Rack Configuration Software.

    • Backplane communication fault: If TX/RX LED is not flashing, reseat the module and check adjacent modules for the same symptom.

    Q5: What spare parts are available for the 3500/32-01-00?

    Key spares include:

    • 125712-01: Spare 4-Channel Relay Module (main card) 

    • 125720-01: Spare 4-Channel Relay I/O Module (for standard applications) 

    • 125720-02: Spare 4-Channel Relay I/O Module (for hazardous area/functional safety) 

    • 129771-01: 3500/32 and 3500/32M Relay Module User Guide