Beckhoff KL3208-0010 8-Channel Analog Input Terminal

The KL3208-0010 is an eight-channel analog input terminal from the Beckhoff Bus Terminal series (KL series) for the traditional K-Bus I/O system, designed for direct connection of resistance temperature detectors (RTDs). It measures the resistance of PT100/PT1000 sensors and converts it to temperature values for the controller. The -0010 suffix denotes a specific variant of the KL3208; its exact functional differences versus the standard KL3208 must be confirmed in the current Beckhoff datasheet. It is the high-density member of the KL320x RTD input family. Unlike EtherCAT terminals (EL series), the KL series communicates via the K-Bus and is typically used with Beckhoff Bus Couplers or Bus Terminal Controllers.

  • Item No :

    KL3208-0010
  • Order(MOQ) :

    1
  • Payment :

    EXW
  • Product Origin :

    Germany
  • Shipping Port :

    Wuhan, Hubei, China
  • Lead Time :

    3-5 days
  • Weight :

    0.5kg
  • Overview

    Product display

    KL3208-0010 Original New in Stock

     

     

     

     

     

     

     

     

     

     

    Parameters

     
     
    Parameter Specification
    Product Name KL3208-0010
    Series Bus Terminal (KL Series, K-Bus)
    Function RTD input (temperature measurement)
    Number of Channels 8 (RTD inputs)
    Sensor Types PT100, PT1000 (confirm supported sensor types for the -0010 variant in datasheet)
    Connection Technology 2-/3-/4-wire connection (confirm supported modes for the -0010 variant in datasheet)
    Resolution 0.1 °C (typical); confirm exact resolution in datasheet
    Accuracy Confirm exact accuracy class in datasheet
    Measurement Range Confirm exact temperature range in datasheet (e.g., -200 °C … +850 °C for PT sensors)
    Conversion Time Confirm conversion time in datasheet
    Electrical Isolation 500 V (channel to bus); confirm isolation ratings in datasheet
    K-Bus Interface K-Bus (backplane of the Bus Terminal system)
    Current Consumption Typically from K-Bus; confirm exact value in datasheet
    Diagnostics Channel-wise status LEDs; confirm available diagnostic functions (e.g., wire break) in datasheet
    Configuration Via Bus Coupler/Controller configuration (e.g., KS2000 or TwinCAT); confirm in datasheet
    Operating Temperature 0 °C … +55 °C
    Storage Temperature -25 °C … +85 °C
    Dimensions (W × H × D) Typically wider than 12 mm due to 8-channel density; confirm exact width in datasheet
    Weight Confirm in datasheet
    Mounting DIN rail (EN 60715)
    Protection Class IP20
    Approvals CE, UL (depending on variant)

    Note: The -0010 suffix denotes a specific variant of the KL3208. Variant suffixes can indicate different hardware revisions, wiring configurations, or feature sets. Always verify the exact technical differences between KL3208 and KL3208-0010 in the current official Beckhoff datasheet before design-in. Exact sensor support, resolution, accuracy, and terminal width must also be confirmed.

    Core Advantages

    1. Eight RTD Inputs in One Terminal
    Eight independent RTD input channels in a single Bus Terminal housing — very high channel density for multi-point temperature measurement in K-Bus systems, significantly reducing cabinet space.

    2. Direct RTD Connection
    Connects PT100/PT1000 resistance temperature detectors directly to the Bus Terminal, providing temperature measurement without external transmitters.

    3. 2-/3-/4-Wire Connection Support
    Supports multiple wiring modes, with 3- and 4-wire connection compensating for line resistance. Confirm the exact supported modes for the -0010 variant in the datasheet.

    4. High-Resolution Temperature Measurement
    Typically 0.1 °C resolution for fine temperature measurement. Confirm the exact resolution in the datasheet.

    5. K-Bus System Integration
    Integrates into the Beckhoff Bus Terminal system via the K-Bus, working with Bus Couplers and Bus Terminal Controllers for fieldbus connectivity.

    6. Channel-Wise Diagnostic Capability
    Status LEDs and wire-break detection (where supported) support commissioning and fault identification.

    7. Compact and Robust Industrial Design
    IP20-rated, DIN-rail mounted, with electrical isolation between the input channels and the K-Bus.

    Applications

    • Machine building — high-density temperature monitoring of bearings, motors, and gearboxes.

    • Process technology — multi-point temperature measurement in process plants.

    • HVAC and building automation — duct and pipe temperature measurement across many points.

    • Legacy K-Bus systems — expansion and maintenance of existing Bus Terminal installations.

    • OEM equipment — embedded multi-point temperature sensing in industrial machines.

    • Test benches — precise multi-channel temperature acquisition in validation and R&D rigs.

    • Food and pharmaceutical — temperature monitoring in regulated processes.

    FAQ

    Q1: What is the KL3208-0010 used for?
    It is an 8-channel RTD input terminal for the Beckhoff K-Bus Bus Terminal system, used to measure temperature with PT100/PT1000 resistance temperature detectors across eight points.

    Q2: What is the difference between KL3208 and KL3208-0010?
    The -0010 suffix denotes a specific variant of the KL3208. The exact functional or hardware differences must be confirmed in the current Beckhoff datasheet — do not assume equivalence between the two order numbers.

    Q3: What is the difference between KL3204 and KL3208-0010?
    The KL3204 provides 4 RTD input channels; the KL3208-0010 provides 8 channels. Choose based on the number of temperature measurement points required.

    Q4: Which sensor types are supported?
    PT100 and PT1000 are typically supported. Confirm the exact supported sensor types for the -0010 variant in the current datasheet.

    Q5: Does it support 3-wire and 4-wire connection?
    2-, 3-, and 4-wire connection are typically supported; confirm the exact supported modes for the -0010 variant in the current datasheet.

    Q6: How is the terminal configured?
    Configuration is performed through the Bus Coupler or Bus Terminal Controller (e.g., via KS2000 or TwinCAT). Confirm the exact workflow in the datasheet.

    Q7: Does it require an external 24 V supply?
    The terminal logic is powered from the K-Bus. Confirm the exact supply requirements in the datasheet.

    Q8: Is the KL3208-0010 suitable for safety functions?
    No. It is a standard automation terminal and is not a certified safety component. Use appropriately certified hardware for safety-related temperature monitoring.

    Recommending Models

     

     
     
    Model Description When to Choose
    KL3208-0010 8-channel RTD input, specific variant (K-Bus) When the -0010 variant's specific characteristics are required
    KL3208 8-channel RTD input, standard variant (K-Bus) Standard 8-channel RTD measurement (confirm differences in datasheet)
    KL3204 4-channel RTD input, PT100/PT1000 (K-Bus) Four RTD measurement points
    KL3202 2-channel RTD input, PT100/PT1000 (K-Bus) Two RTD measurement points
    EL3208 8-channel RTD input (EtherCAT) EtherCAT system instead of K-Bus
    EL3204 4-channel RTD input (EtherCAT) Four RTD inputs in an EtherCAT system
    KL3318 8-channel thermocouple input (K-Bus) Thermocouples instead of RTDs
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.