Beckhoff KL3201 1-Channel Analog Input Terminal

The KL3201 is a single-channel analog input terminal from the Beckhoff Bus Terminal series (KL series) for the traditional K-Bus I/O system, designed for direct connection of resistance temperature detectors (RTDs). It measures the resistance of PT100/PT1000 sensors and converts it to a temperature value for the controller. Unlike EtherCAT terminals (EL series), the KL series communicates via the K-Bus and is typically used with Beckhoff Bus Couplers or Bus Terminal Controllers.

  • Item No :

    KL3201
  • Order(MOQ) :

    1
  • Payment :

    EXW
  • Product Origin :

    Germany
  • Shipping Port :

    Wuhan, Hubei, China
  • Lead Time :

    3-5 days
  • Weight :

    0.5kg
  • Overview

    Product display

    KL3201 Original New in Stock

     

     

     

     

     

     

     

     

     

     

     

    Parameters

     
     
    Parameter Specification
    Product Name KL3201
    Series Bus Terminal (KL Series, K-Bus)
    Function RTD input (temperature measurement)
    Number of Channels 1 (RTD input)
    Sensor Types PT100, PT1000 (confirm supported sensor types in datasheet)
    Connection Technology 2-/3-/4-wire connection (confirm supported modes in datasheet)
    Resolution 0.1 °C (typical); confirm exact resolution in datasheet
    Accuracy Confirm exact accuracy class in datasheet
    Measurement Range Confirm exact temperature range in datasheet (e.g., -200 °C … +850 °C for PT sensors)
    Conversion Time Confirm conversion time in datasheet
    Electrical Isolation 500 V (channel to bus); confirm isolation ratings in datasheet
    K-Bus Interface K-Bus (backplane of the Bus Terminal system)
    Current Consumption Typically from K-Bus; confirm exact value in datasheet
    Diagnostics Status LED; confirm available diagnostic functions (e.g., wire break) in datasheet
    Configuration Via Bus Coupler/Controller configuration (e.g., KS2000 or TwinCAT); confirm in datasheet
    Operating Temperature 0 °C … +55 °C
    Storage Temperature -25 °C … +85 °C
    Dimensions (W × H × D) 12 mm × 100 mm × 68 mm (typical KL housing)
    Weight Approx. 50 g
    Mounting DIN rail (EN 60715)
    Protection Class IP20
    Approvals CE, UL (depending on variant)

    Note: Specifications are indicative. The KL3201 is a K-Bus RTD input terminal. Exact supported sensor types, wiring modes, resolution, accuracy, temperature range, and diagnostic functions must be verified against the current Beckhoff datasheet for your revision. The KL series differs from the EtherCAT EL series in the bus system used.

    Core Advantages

    1. Direct RTD Connection
    Connects PT100/PT1000 resistance temperature detectors directly to the Bus Terminal, providing temperature measurement without external transmitters.

    2. 2-/3-/4-Wire Connection Support
    Supports multiple wiring modes, with 3- and 4-wire connection compensating for line resistance to improve measurement accuracy. Confirm the exact supported modes in the datasheet.

    3. High-Resolution Temperature Measurement
    Typically 0.1 °C resolution for fine temperature measurement. Confirm the exact resolution in the datasheet.

    4. K-Bus System Integration
    Integrates into the Beckhoff Bus Terminal system via the K-Bus, working with Bus Couplers and Bus Terminal Controllers for fieldbus connectivity.

    5. Diagnostic Capability
    Status LED and wire-break detection (where supported) support commissioning and fault identification.

    6. Compact and Robust Industrial Design
    IP20-rated, DIN-rail mounted, with electrical isolation between the input channel and the K-Bus.

    Applications

    • Machine building — temperature monitoring of bearings, motors, and gearboxes with PT100/PT1000 sensors.

    • Process technology — temperature measurement in process plants.

    • HVAC and building automation — duct and pipe temperature measurement.

    • Legacy K-Bus systems — expansion and maintenance of existing Bus Terminal installations.

    • OEM equipment — embedded temperature sensing in industrial machines.

    • Test benches — precise temperature acquisition in validation and R&D rigs.

    • Food and pharmaceutical — temperature monitoring in regulated processes.

    FAQ

    Q1: What is the KL3201 used for?
    It is a 1-channel RTD input terminal for the Beckhoff K-Bus Bus Terminal system, used to measure temperature with PT100/PT1000 resistance temperature detectors.

    Q2: What is the difference between KL3201 and KL3202?
    The KL3201 provides 1 RTD input channel; the KL3202 provides 2 channels. Choose based on the number of temperature measurement points required.

    Q3: Which sensor types are supported?
    PT100 and PT1000 are typically supported. Confirm the exact supported sensor types in the current datasheet.

    Q4: Does it support 3-wire and 4-wire connection?
    2-, 3-, and 4-wire connection are typically supported; 3- and 4-wire modes compensate for line resistance. Confirm the exact supported modes in the current datasheet.

    Q5: What resolution does it provide?
    Typically 0.1 °C resolution, but the exact resolution must be confirmed in the current datasheet.

    Q6: How is the terminal configured?
    Configuration is performed through the Bus Coupler or Bus Terminal Controller (e.g., via KS2000 or TwinCAT). Confirm the exact workflow in the datasheet.

    Q7: Does it require an external 24 V supply?
    The terminal logic is powered from the K-Bus. Confirm the exact supply requirements in the datasheet.

    Q8: Is the KL3201 suitable for safety functions?
    No. It is a standard automation terminal and is not a certified safety component. Use appropriately certified hardware for safety-related temperature monitoring.