Allen Bradley 1747-KFC15 SLC 500 ControlNet RS‑232 Interface Module New in Stock

he Allen‑Bradley 1747‑KFC15 is a ControlNet RS‑232 Interface Module for the SLC 500 platform that acts as a DF1‑to‑ControlNet bridge. It connects SLC 5/03, 5/04, or 5/05 processors to a ControlNet network via the processor's Channel 0 serial port, enabling deterministic data exchange with ControlNet‑capable HMIs, drives, and other controllers.

  • Item No :

    1747-KFC15
  • Order(MOQ) :

    1 Piece
  • Payment :

    EXW
  • Product Origin :

    USA
  • Shipping Port :

    Wuhan
  • Lead Time :

    3-5days
  • Weight :

    3KG
  • Product Details

     
     
    Specification Description
    Manufacturer Rockwell Automation (Allen‑Bradley)
    Model 1747‑KFC15
    Product Family SLC 500
    Product Type ControlNet RS‑232 Interface Module / DF1‑to‑ControlNet Bridge
    Compatible Processors SLC 5/03, 5/04, 5/05
    Network Protocol ControlNet (Coaxial media, 5 Mbps)
    Serial Protocol RS‑232 DF1 Full‑Duplex or Half‑Duplex
    Chassis Location Any I/O slot except Slot 0 (reserved for processor)
    Backplane Current Draw 150 mA @ 5V DC; 40 mA @ 24V DC
    Connectors 1 x BNC (ControlNet coaxial tap), 1 x RS‑232 port, 1 x Network Access Port (NAP)
    Cable Type Belden 9463 (ControlNet coaxial)
    DIP Switch / Rotary Node address dials (tens/units) + DIP switch banks for configuration
    Operating Temperature 0°C to +60°C
    Weight Approx. 0.25 kg
    Product Status Discontinued / Legacy (available as spare/used)

    Related Product Model Recommendations

     
     
    Model Description Typical Application
    1747‑SCNR ControlNet scanner module for SLC 500 Required for controlling distributed ControlNet I/O; works alongside KFC15 for messaging
    1747‑KFC15/A Series A revision of the same module Alternative revision variant
    1747‑CP3 Null‑modem serial cable for SLC processor connection Required to connect KFC15 to SLC Channel 0
    1747‑L541 / L542 / L543 SLC 5/04 processors Target controllers for KFC15 integration
    1756‑CN2 / 1756‑CN2R ControlNet bridge modules for ControlLogix Network integration with ControlLogix systems
    1784‑PCIC / 1784‑PCICS ControlNet PCMCIA/PCI cards for PC Programming terminal access (alternative to NAP)
    20F1ANC302JN0NNNNN  1756-L82ES IE-3300-8T2S-E
    20G11NC022AA0NNNNN 1756-IRT8I   22C-D-038 A103
    20BC140A0AYNANCO   1756-OF8H 22C-D-060 A103
    20BC105A0AYNANCO   1756-IF16H 22C-D-088 A103
    20BC056A0AYNANCO   1756-L71 5069-L3100ERM
    20AC030A0AYNANC0 1756-L72 5069-L310ERM
    20BC140A0AYNANC0 1756-L73 5069-L310ERS2
    20AD040A0AYNANC0 1756-L74 1747-L552C 
    20BC037AOAYNANCO 1756-EN2T  1785-L40L
    20AC8P7A0 AYNANCO 1756-EN2TR 2094-BM01-S
    2711P-K6M20D 1756-RM2 1769-L33ERM
    2711P-T10C22D9P 1756-PAR2 1769-OF8C
    2711-K10C3 1756-A4 1769-IF8
    2711-K5A2 1756-RMC1 1769-IF16C
    2711-K5A20  1756-PAR2 1769-IR6
    2711P-T10C4D8 1756-N2 1769-OW16
    2711P-T7C22D9P  1756-A10 1769-PA4
    2711P-RP8D 1756-IF16 1747-L553/C
    2711P-T12W22D9P 1756-OF8 1783-LMS8
    2711P-T7C21DBS  1756-IB16 1783-USBT

    Payment & Delivery

    FAQs

    Q1: What is the primary function of the 1747‑KFC15?

    It is a DF1‑to‑ControlNet bridge. It allows an SLC 5/03, 5/04, or 5/05 processor (which only has a serial port) to communicate on a ControlNet network with HMIs, drives, and other devices. It connects to the SLC via the Channel 0 RS‑232 serial port, not through the backplane.

    Q2: Can the 1747‑KFC15 control ControlNet distributed I/O modules?

    No. The KFC15 is strictly an interface/messaging module for bridging serial data and programming terminals onto ControlNet. For I/O control, you must use the 1747‑SCNR scanner module in addition to the KFC15.

    Q3: What is the Network Access Port (NAP) used for?

    The NAP (8‑pin mini‑DIN) allows a programming terminal to connect directly to the ControlNet network without disrupting the physical coaxial wiring. This is a critical feature for troubleshooting and online programming without causing a plant‑wide communication fault.

    Q4: Which SLC processors are compatible with the 1747‑KFC15?

    The module is compatible with SLC 5/03, 5/04, and 5/05 processors. It connects to the processor via the Channel 0 RS‑232 port using a null‑modem cable (e.g., 1747‑CP3).

    Q5: What configuration tools are required?

    Configuration requires:

    • RSNetWorx for ControlNet – for scheduling the ControlNet network and defining Keeper attributes

    • RSLogix 500 – for configuring SLC Channel 0 parameters (Baud rate, parity, DF1 Full Duplex mode) to match the KFC15 DIP switch settings

    • RSLinx Classic – for PC communication setup using the "RS‑232 DF1 Devices" driver, selecting device type as "1770‑KF2/1785‑KE/1747‑KFC15".

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.