Allen Bradley 1746-NI4 SLC 500 High Resolution Analog Input Module 4 Point

The Allen‑Bradley 1746‑NI4 is a 4‑channel analog input module for the SLC 500 programmable controller family. It accepts voltage (±10V DC) or current (±20mA) signals from field devices such as pressure transmitters, temperature sensors, and level transducers, converting them into digital values for use in the PLC's control program.

  • Item No :

    1746-NI4
  • Order(MOQ) :

    1 Piece
  • Payment :

    EXW
  • Product Origin :

    USA
  • Shipping Port :

    Wuhan
  • Lead Time :

    3-5days
  • Weight :

    3KG
  • Product Details

     
     
    Specification Description
    Manufacturer Rockwell Automation (Allen‑Bradley)
    Model 1746‑NI4
    Product Family SLC 500 Analog I/O 
    Product Type Analog Input Module
    Input Channels 4 (differential, non‑isolated) 
    Input Signal Ranges ±10V DC (voltage mode) or ±20mA (current mode), per‑channel selectable 
    Resolution 16 bits (1 LSB = 305.176 µV voltage; 1.22070 µA current) 
    Conversion Method Delta‑Sigma Modulation 
    Update Time 512 µs per channel 
    Step Response 60 ms (95%) 
    Input Impedance 1 MΩ (voltage), 250 Ω (current) 
    Accuracy (25°C) ±0.284% full scale (voltage); ±0.365% full scale (current) 
    Backplane Current Draw 25 mA @ 5V DC; 85 mA @ 24V DC 
    Chassis Location Any I/O slot except Slot 0 (reserved for processor) 
    Operating Temperature 0°C to +60°C 
    Connector Removable terminal block (RTB) 
    Status Indicators Module status LED 
    Configuration DIP switches on circuit board, per channel 
    Module Keying Analog I/O key position 
    Lifecycle Status Discontinued / Legacy (SLC 500 platform officially discontinued March 2024)

    Related Product Model Recommendations

     
     
    Model Description Typical Application
    1746‑NIO4I 2 analog inputs + 2 analog outputs (current) in one module Compact applications needing both I/O in one slot 
    1746‑NO4I 4‑channel analog output module (current) Output counterpart for 4‑20mA control loops 
    1746‑NI16I / NI16V 16‑channel high‑density analog input modules Applications requiring more input channels; not drop‑in replacement, requires I/O config rewrite 
    1746‑NI4‑CC Conformal coated version for harsh environments Humid, dusty, or corrosive installations 
    1747‑L541 / L542 / L543 SLC 5/04 processors Target controllers for 1746‑NI4 integration
    1746‑P1 / P2 / P3 SLC 500 power supplies Power for chassis and modules

     

    1746-NT8 1794-IE8XT 1769-IF4I
    1756-A13 1794-IF2XOF2I 1769-IF4XOF2
    1756-A17 1794-IF4I 1769-IF8
    1746-NI4 1794-IF8IH 1769-IG16
    1756-A7 1746-NO4V 1769-IM12
    1756-BA1 1794-IH16 1769-IQ16
    1756-BA2 1794-IJ2 1769-IQ16F
    1756-BATA 1794-IM16 1769-IQ32
    1756-BATM 1794-IM8 1769-IQ32T
    1756-CFM 1794-IP4 1769-IQ6XOW4
    1756-CN2 1794-IR8 1769-IR6
    1756-CN2R 1794-IRT8 1769-IT6
    1756-CNB 1794-IRT8K 1769-OA16

     

    Payment & Delivery

     

    FAQs

    Q1: How do I select between voltage and current input on the 1746‑NI4?

    Each of the 4 channels has a DIP switch on the circuit board. Setting the switch ON selects current mode (±20mA); setting it OFF selects voltage mode (±10V). Ensure the field device signal type matches the DIP switch setting—connecting a voltage source to a current‑configured channel may damage the module .

    Q2: How are the input channels addressed in the PLC program?

    If the module is installed in Slot 5, the input words are mapped as follows:

    • Channel 0 → I:5.0

    • Channel 1 → I:5.1

    • Channel 2 → I:5.2

    • Channel 3 → I:5.3

    Each is a signed 16‑bit integer. The raw count range depends on signal type: ±20mA gives counts from –16,384 to +16,384; ±10V gives –32,768 to +32,767 .

    Q3: What raw counts should I use for scaling a 4‑20mA transmitter?

    For a 4‑20mA signal:

    • 4 mA (minimum) → 3277 counts (under‑range value)

    • 20 mA (maximum) → 16384 counts

    Use these as InputMin and InputMax in the SCP (Scale with Parameters) instruction, and map them to your engineering units (e.g., 0–100 PSI). If the reading is stuck at 3277, the loop is likely open or polarity is reversed .

    Q4: Is the 1746‑NI4 still in production?

    No. The SLC 500 platform was formally discontinued by Rockwell Automation on March 31, 2024. The 1746‑NI4 is now only available through the used, refurbished, or third‑party market. For new projects, Rockwell recommends migrating to the CompactLogix 5380 platform with appropriate analog I/O modules .

    Q5: What is the difference between the 1746‑NI4 and the 1746‑NIO4I?

    The 1746‑NI4 is a pure analog input module with 4 input channels. The 1746‑NIO4I is a combination module featuring 2 analog inputs and 2 analog outputs in a single slot. The input section scaling and addressing on the NIO4I is identical to the NI4, making it a good choice for compact PID control loops.