Recommended Models & Related Products
Replacement Note: When migrating to the successor 3RT2037-1KB40, verify that the S3 frame dimensions and terminal arrangement are compatible with your existing panel layout. The 3RT2 series is the current SIRIUS platform, but it may require minor wiring adjustments compared to the 3RT1.
What's Included
Note: Auxiliary contacts, overload relay, and DIN rail are sold separately.
Why Buy From Us?
-
In Stock – Ready to ship immediately
-
Tested – Each unit verified for functionality
-
Warranty Included – 12-month warranty for purchase confidence
-
Technical Support – Contactor and successor migration assistance available
Frequently Asked Questions (FAQ)
Q1: What is the Siemens 3RT1044-1BB40?
It is a SIRIUS 3RT1 power contactor with 3 poles, 3 NO main contacts, and a 24 V DC coil. It is rated for 65 A in AC-3 and 30 kW at 400 V, in the Size S3 frame with screw terminals.
Q2: Is this product still in production?
No. It was discontinued effective October 1, 2020 (PM490 status). It is available only through remaining stock, refurbished units, or third-party suppliers .
Q3: What is the successor model?
The preferred successor is 3RT2037-1KB40 from the SIRIUS 3RT2 series .
Q4: What is the coil voltage?
The coil is rated for 24 V DC .
Q5: What is the motor power rating?
The contactor is rated for 30 kW at 400 V in AC-3 (motor load) and 100 A in AC-1 (resistive load) .
Q6: How many auxiliary contacts does it have?
The basic unit has no integrated auxiliary contacts (0 NO + 0 NC). Auxiliary contact blocks can be added up to a maximum of 8 blocks (with no more than 4 NC) .
Q7: What are the dimensions and weight?
Approximately 70 × 146 × 152 mm and 2.77–2.83 kg .
Q8: Does this contactor include overload protection?
No. A separate overload relay (such as the 3RU1146 series) must be installed in the motor feeder for overload protection.
Q9: What is the operating temperature range?
The operating range is -25 to +60 °C .
Q10: What should I verify before ordering?
Always verify the exact part number (3RT1044-1BB40), confirm your motor current and power requirements (65 A AC-3 / 30 kW at 400 V), ensure your control voltage is 24 V DC, and check whether you should migrate to the successor 3RT2037-1KB40 for new installations.