New Siemens 6ES7417-4XL04-0AB0 SIMATIC S7-400 CPU Central Processing Unit

The Siemens 6ES7417-4XL04-0AB0 is a SIMATIC S7-400 CPU 417-4 central processing unit, designed for high-performance automation applications in large-scale industrial plants. The module includes an MPI/DP interface and a dedicated PROFIBUS DP port, with two additional slots for plug-in IFM modules for expanded communication capability.

  • Item No :

    6ES7417-4XL04-0AB0
  • Order(MOQ) :

    1 Piece
  • Payment :

    EXW
  • Product Origin :

    Germany
  • Shipping Port :

    Wuhan
  • Lead Time :

    3~5 days
  • Weight :

    3kg
  • Product Details

     
     
    Specification Description
    Manufacturer Siemens
    Model 6ES7417-4XL04-0AB0
    Product Family SIMATIC S7-400
    Product Type CPU 417-4 Central Processing Unit
    Work Memory 20 MB total (10 MB code + 10 MB data) 
    Integrated Load Memory 256 KB RAM 
    Expandable Load Memory FEPROM (FLASH) up to 64 MB; RAM up to 64 MB via Memory Card 
    Processing Times Bit: 0.03 µs; Word: 0.03 µs; Fixed-point: 0.03 µs; Floating-point: 0.09 µs 
    Interface 1 MPI, 12 Mbit/s 
    Interface 2 PROFIBUS DP 
    Interface 3 & 4 Pluggable IFM modules (IF 964-DP) 
    Max. DP Devices 125 
    Max. I/O Address Area 16 KB inputs / 16 KB outputs (total) 
    S7 Counters 2,048 
    S7 Timers 2,048 
    Data Blocks (DB) Max. 8,191 (DB 0 reserved); max. 64 KB each 
    Function Blocks (FB) Max. 6,144 
    Function Calls (FC) Max. 6,144 
    Backplane Current Draw 1.7 A @ 5 V DC 
    Power Loss Typ. 6 W 
    Backup Battery Yes, all data buffered; typ. 600 µA backup current 
    Dimensions (W x H x D) 219 mm x 290 mm x 50 mm 
    Weight Approx. 1.238 kg 
    Engineering Software STEP 7 V5.2 SP1 HF3 or higher with HW update 
    Firmware Version V4.0 
    Country of Origin Germany (DE) 
    Lifecycle Status Discontinued (January 1, 2021) – replaced by 6ES7417-4XT07-0AB0 

    Related Product Model Recommendations

     
     
    Model Description Typical Application
    6ES7417-4XL04-0AB0 (this model) CPU 417-4, 20 MB, MPI/DP, 2x IFM slots Large-scale automation (discontinued)
    6ES7417-4XT07-0AB0 Official replacement – CPU 417-4, 30 MB (15 MB code + 15 MB data), MPI/DP, 2x IFM slots  Migration path for new installations
    6ES7417-4XT05-0AB0 CPU 417-4, 30 MB work memory, successor variant  Alternative replacement option
    6ES7416-3XL00-0AB0 CPU 416-3, 3.2 MB work memory Smaller-scale applications
    6ES7417-5HT06-0AB0 CPU 417-5H PN/DP, redundant, 32 MB High-availability systems
    6ES7964-2AA04-0AB0 Plug-in IFM module (IF 964-DP) Additional PROFIBUS DP interface
    6ES7954-8Lxxx-0AA0 Memory Card (FLASH/RAM) for load memory expansion Program and data storage

    Payment & Delivery

    FAQs

    Q1: Is the 6ES7417-4XL04-0AB0 still in production?

    No. This CPU was discontinued by Siemens on January 1, 2021 . It is now available only through aftermarket suppliers and as spare parts for existing installations. The official replacement is the 6ES7417-4XT07-0AB0, which offers 30 MB work memory (15 MB code + 15 MB data) compared to the 20 MB of this model .

    Q2: What is the difference between 6ES7417-4XL04-0AB0 and 6ES7417-4XT07-0AB0?

    The 6ES7417-4XT07-0AB0 is the direct successor with increased work memory (30 MB vs. 20 MB). Both CPUs have the same processing speed (0.03 µs bit operations), MPI/DP interfaces, and two plug-in IFM module slots. The 4XT07 is recommended for new installations and as the migration path for discontinued 4XL04 units .

    Q3: What software is required to program this CPU?

    The 6ES7417-4XL04-0AB0 requires STEP 7 V5.2 SP1 HF3 or higher with the appropriate Hardware Update (HW-Update) . It supports STEP 7 Classic (V5.x) and is not directly configurable in TIA Portal – users have reported difficulties finding it in TIA Portal V14 hardware catalog .

    Q4: Can this CPU be used in redundant (H) systems?

    No. The 6ES7417-4XL04-0AB0 is a standard (non-redundant) CPU. For redundant high-availability applications, the CPU 417-5H series (e.g., 6ES7417-5HT06-0AB0) is required, which supports S7-400H fault-tolerant configurations with bumpless switchover .

    Q5: What are the common causes of "SF" (System Fault) LED errors?

    Common causes include:

    • Firmware/configuration mismatch: Ensure the hardware configuration matches the actual firmware version (V4.0) 

    • Memory Card issues: Verify the Memory Card (FLASH/RAM) is properly inserted and formatted 

    • Battery failure: The CPU uses a backup battery to buffer all data; check battery voltage and replace if needed 

    • Bus communication errors: Check PROFIBUS DP cable, connectors, and termination

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.